HLM Hydraulics
FRED Login

Pilot build 0.9.0 · Site laboratory software

FRED — Field Rheology & Evaluation Dashboard

Slurry testing your site laboratory can run, step by step. FRED imports each rotational test from the instrument's own export and takes it through oven checks, rheogram fits, and a saved concentration calibration to traceable records — on the Windows lab PC, with or without a connection.

RUN 03 · FULL BOB 25.0 °C Demonstration data
τ₀ ≈ 12 Pa
Step
— / 9
Shear rate
— s⁻¹
Shear stress
— Pa
Bingham fit
pending
Indicative rheogram from synthetic demonstration data. Open points sit outside the method's fitting range. Not a validated test result.

§ 01

Seven steps.
One main action at a time.

Each sample moves from the instrument export to a saved concentration calibration. Operators see what they've saved and what each point still needs. Every step works on the PC with no connection.

Tests run on the instrument in Anton Paar RheoCompass. FRED imports and analyses the exports; it doesn't control the instrument.

  1. 01

    Record the sample

    Sample code, source, and collection details, so every test and result stays linked to the material it came from.

  2. 02

    Run the tests in RheoCompass

    An edge-effect run and a full-bob run at each concentration, named as a pair. A subsample of each goes into a weighed beaker for oven drying.

  3. 03

    Import and pair

    FRED keeps the original export and its fingerprint, pairs each full-bob run with its edge-effect run, and records the cup and bob and the procedure checklist.

  4. 04

    Oven check each point

    Beaker, wet, and dry masses give each point's solids concentration. Weighings can be entered in one table or filled from a balance file.

  5. 05

    Review each rheogram

    Edge-effect torque is subtracted point by point. The operator checks the suggested linear range and saves the Bingham fit. Findings are explained, not hidden.

  6. 06

    Save the calibration

    Select the points, and yield stress and plastic viscosity are fitted against concentration on the PC. Each save is a numbered revision, bounded to the tested range.

  7. 07

    Report and back up

    Result sheets and a full evidence report from a saved revision, PDF and Excel records, and a database backup at the end of the day.

§ 02

A slurry testing suite,
starting with flow.

Rotational viscometry comes first. The rest of the suite follows, so a site laboratory can run its routine slurry tests in one place.

Test What it covers Status
Rotational viscometry RheoCompass import, paired edge-effect and full-bob runs, torque subtraction, rheograms, and saved concentration calibrations. In pilot build
Slurry concentration Oven drying with container-corrected masses for each tested point, entered one by one or in a weighings table. In pilot build
Solids density Density of the solids phase, linked to concentration basis conversions. Planned
Settled bed density A separate test for how the solids pack when they settle. Planned
Particle size distribution PSD results linked to the sample, so they aren't retyped for each run. Planned

§ 03

The lab PC is
where the work lives.

Staff open FRED in Edge or Chrome and select Install. From then on it runs from the PC. Import, analysis, calibration, and export never wait on the network. Cloud account builds first need online preparation, and offline work lasts for the saved access period. Reconnect before it expires; signing out locks that PC.

  • RheoCompass import and oven checkslocal
  • Rheograms and Bingham fitslocal
  • Concentration calibrations, saved as revisionslocal
  • PDF and Excel recordslocal
  • Database backup and restorelocal
  • Optional: technician data-quality review by HLM returned On PCs connected to the HLM service, requests go straight out and reviews come back to the PC.

§ 04

Where FRED stands
today.

FRED is in a local pilot, with optional cloud accounts tested on a local server. We'd rather show you the boundaries than have you discover them.

0.9.0 In the pilot build

  • RheoCompass import with paired edge-effect and full-bob runs
  • Oven-drying concentration for each point, with container subtraction
  • Concentration calibrations calculated and saved on the PC as revisions
  • Saved equipment profiles, certified-fluid register, and instrument checks
  • Calibration comparison across samples
  • Sample result sheets and PDF and Excel test records with rheograms
  • Optional cloud build: sign-in, company/site administration, offline access periods and record/file sync tested locally

Next Still to come

  • Method validation with a real sample and reference datasets
  • Laboratory procedure review of help text
  • Hosted release for client sites
  • Hosted cloud delivery and representative multi-PC client acceptance
  • Solids density, settled bed density, and PSD tests

§ 05

Part of the HLM Hydraulics family.

FRED stands on its own. Its identifiers, revisions, and calibration exports are designed to link with HLM's pipeline products later, without moving your data.

You are here

FRED

Guided slurry testing in the site laboratory. Measured rheology and concentration, recorded where they're taken.

Reporting

FlowIQ

Turns SCADA historian exports into hydraulic performance reports.

Monitoring

Horizon

A slurry pipeline monitoring dashboard with per-mine rheology calibrations.

Visit HLM Hydraulics

§ 06

Pilot FRED
at your site.

We're preparing the first supported pilots. Contact HLM Hydraulics to discuss your laboratory, instrument and testing workflow.

Discuss a supported pilot

This page does not collect enquiry details.

Use HLM Hydraulics' website to get in touch. Pilot access follows agreed onboarding.

Contact HLM Hydraulics